Share

Version

Associated programs

Other improvements and corrections

The 2021.d version of CYPECAD also includes other minor program improvements and corrections of issues that could occur in unique cases:

  • The "Surface loads on panels" option has been improved and users can select panels that are completely surrounded by others.
  • Warnings when assigning walls that appeared repetitively have been eliminated.
  • The values of the "Groups" > "Options – 3D view" option are saved.
  • The values that are shown in the "Damping" help box of the "Norma de Construcción Sismorresistente NCSE-02" have been corrected.
  • After using the "Loads" > "Change loadcase assignment" option, the floors on which changes have been carried out are automatically saved.
  • An error in the "Reinforcement quantities, per diameter" report has been solved. When the "Detail base reinforcement on drawings" option was active, the base reinforcement total was twice the actual value in the summary of the quantities.
  • An error has been solved, which caused an increase in the length of a frame in cases as shown in the image.
  • An error has been solved that occurred when users tried to obtain the frames drawing having deleted all the sections when the frame had been edited.
  • An error has been solved that occurred when users consulted the deformed shape having deleted loadcases that had been consulted previously.
  • An error has been solved that occurred when users cancelled the selection of the form in "Panel manager > Waffle slabs > Import from library".
  • An error has been solved that occurred when stairs were entered in groups that had been added below foundation level, which caused for them to be added to the group above.