Terminal units. Heat recovery unit
This terminal unit represents a heat recovery unit installed in the thermal zone.
| Note: |
|---|
| This type of terminal unit is stand-alone and is defined directly in the "Terminal units" section for each zone, without requiring an air-conditioning system to be entered in the "Air-conditioning systems" section. |
Generic
The "Generic" option lets you simulate a generic heat recovery unit located in the thermal zone.
In this type of heat recovery unit, the "Heat exchanger", "Fans" and "Outdoor air bypass" can be configured in the following sections:
Heat exchanger
The "Heat exchanger" section lets you configure the following parameters:
- Sensible effectiveness
- Latent effectiveness (optional)
- Advanced settings:
- Heat exchanger type (Plate / Rotary)
- Frost control type (None / Exhaust air recirculation / Exhaust only / Minimum exhaust temperature)
Fans
The "Fans" section lets you configure the following settings:
- Specific power
- Advanced settings:
- Maximum air flow rate (optional)
- Motor efficiency
- Motor heat losses fraction in air stream
| Note: |
|---|
| This unit contains two identical fans, one on the supply side and one on the extract side. You only need to define the characteristics of one of the fans. The unit delivers the total ventilation air flow rate defined for the zones to which it is connected. The electrical power of its fans is calculated on the basis of this flow rate. |
Outdoor air bypass
The "Outdoor air bypass" section lets you configure the following parameters:
- Maximum indoor temperature
- Minimum outdoor temperature
| Note: |
|---|
| The heat recovery unit is fitted with a bypass damper that allows outside air to pass through when this helps to reduce cooling requirements. For this to occur, the following conditions must be met - The indoor temperature is higher than the maximum indoor temperature. - The outdoor temperature is higher than the minimum outdoor temperature. - The outdoor temperature is lower than the indoor temperature. |
Catalogues
The "Catalogues" option lets you simulate a manufacturer’s heat recovery unit installed in the thermal zone.
The heat recovery unit must be selected from the manufacturers and models available in the Open BIM Database, which must first be downloaded via the "Catalogues" option on the main interface.
When selecting this type of heat recovery unit, you can configure the "Outdoor air bypass" in the relevant section.