Update history​

CYPELEC

Links to the CYPE website in the apps help menu

In version 2025.c, new options have been added to the "Help" menu of all CYPE apps, providing direct links to key resources on the CYPE website. These options make it easier to access to useful information and Technical Support, improving the overall experience of using the program.

The new options are the following:

  • Technical support: This link provides information on the different ways of contacting the CYPE Technical Support team to clarify any queries, obtain customised assistance and solve any problem related to the apps.

  • User community: This option provides access to the CYPE user community, where users can share experiences, ask questions and discuss solutions with other professionals using the same tools. This community encourages the exchange of knowledge and best practices, helping to make the most of the program's features.

  • Learning resources: This link leads to a collection of learning resources, such as tutorials, manuals, videos and articles, designed to help you understand and use CYPE apps more efficiently. These materials are designed for all levels of experience, from beginners to advanced users, and are an excellent source of information to expand skills and technical knowledge.

These new additions make it easier to access information and provide the necessary support to improve the users' experience with the apps and to encourage professional development.

Defining the maximum number of decimal places

In version 2025.c, an option has been added to configure the display of significant decimals in the "Bill of quantities" tab in the apps. This new feature is used to adapt the level of numerical precision to the specific needs of each project, providing greater flexibility in the presentation of the data.

To define this configuration, a drop-down menu has been added in the "General parameters" > "Decimals" section, next to the number of decimals in each field, with the following options:

  • Exact number of decimals. Displays all decimals, regardless of whether they are significant figures or not. This option, which is the one used in previous versions, is kept as the default for new projects.

  • Maximum number of decimals. Limits the display to significant figures, up to a user-specified maximum number of decimal places. This option allows for better control of the accuracy of the data, which simplifies the presentation of the information.

This configuration is compatible with the FIEBDC-3 (.bc3) standard, to ensure that adjustments made to the number of decimal places can be read and exported correctly by the data exchange tools available in the app.

Use of hardware acceleration in the drawing tool

As of version 2025.c, the ‘Drawing layouts’ panel uses hardware acceleration for drafting drawings. This implementation allows users to represent and move the model more smoothly.

This panel is present in several CYPE programs, although hardware acceleration is much more noticeable in programs and projects with multiple elements (CYPECAD, CYPE 3D, CYPECAD MEP, etc.).

Changes to the apps available in CYPE Menu

The following modifications have been made to the apps available in the CYPE Menu:

New apps

  • Now, in addition to the apps that are translated into the installation language of the CYPE Menu, there are also apps available in English.

Deleted apps

  • CYPEPLUMBING Solar Systems. Integrated in CYPEPLUMBING.
  • CYPETEL Schematics. Replaced by CYPETEL.
  • CYPELEC Grounding IEC and CYPELEC Grounding IEEE. Integrated into CYPELEC and CYPELEC Distribution.

Incorporating the grounding system design programs (CYPELEC Grounding IEC and CYPELEC Grounding IEEE) into CYPELEC

As of version 2025.c of "CYPELEC" (for REBT, NF and RETIE), the following programs are integrated:

  • CYPELEC Grounding IEC
  • CYPELEC Grounding IEEE

To create a grounding system, the grounding systems panel is enabled within the "Elements library" icon, where the designer can define the grounding system according to the following types:

  • IEC 60364-5-54
  • IEEE Std 80-2000

The use of any of these systems is followed by the final analysis of the total resistance obtained and its check report.

The defined grounding systems, and more specifically the resistance obtained from them, can subsequently be used in the analysis of the diagram of the electrical system, as a parameter for:

  • The grounding resistance of the soil, or
  • The neutral grounding resistance.

To carry out this operation, go to "General conditions" and select the corresponding grounding system from among those created previously.

Update notification available

As of version 2025.b, applications now display a warning message in their initial window when a new update is available. This message provides information about the "installed version" and the "available version", together with a direct link to the Store page of the BIMserver.center web platform.

Clicking on the “Upgrade to the latest version” button automatically starts the download and installation process of the application. This feature ensures that the most current version of the program is always being used, thus benefiting from the latest improvements.

This method replaces the automatic notification and update process of a new version in the BIMserver.center programs available in previous versions.

Visibility of the "Price" and "Amount" columns

As of version 2025.b, Open BIM Quantities allows users to set the visibility of the “Price” and ”Amount” columns in several windows, including the ”Bill of quantities” table, the ”Project database” and the ”Cost databases”.

This configuration is done from the "Columns" option of the "Visualisation" group in the toolbar. Users can choose to hide or show these columns according to their needs, resulting in a more personalised interface focused on the relevant information for each type of project.

This feature is particularly useful for bills of quantities without prices.

New "Bill of quantities (Table)" report

A new report called “Bill of quantities (Table)” has been added to the “BoQ Reports” available from the toolbar in the “Bill of quantities” tab.

This report includes all the concepts defined in the project in a table with the following columns:

  • Code
  • Description
  • Unit
  • Quantity
  • Price
  • Amount

Link to the BIMserver.center Store

In the configuration panel for each application, a direct link to its page in the BIMserver.center web store has been included.

By clicking on the “Go to BIMserver.center Store” button, users are redirected directly to the corresponding page in the Store, where they can learn more about the application, view its features, read reviews from other users and see examples of real contributions.

This feature provides easy access to additional resources and support, enhancing the user experience by providing quick and easy access to all relevant information about the applications.

Information about the license model

An information message has been incorporated into the installation button of the applications so that, before proceeding with the installation, users can identify which applications are free to use (free of charge) and which require licensing permissions (including paid modules).

This enhancement improves the user experience by providing clarity and transparency on the options available to the user based on their license model.

Installing background apps

In the new 2025.b version of CYPE Menu, the background installation feature has been added. Users can now continue working on other tasks while applications are automatically installed in the background.

During the background installation process, the “Installing program” message is displayed next to the applications button in the main CYPE Menu window. Once completed, the message disappears and the application can be run.

This feature is designed to make applications easier to use and manage, improving productivity and the overall experience by minimising waiting time and interruptions during the installation of new applications or upgrades.

Faster rendering of lines and diagrams

The speed of redrawing the single-line diagram is optimised, making the working environment more efficient.

This optimisation also improves any editing operation on electrical lines and circuits (deleting, copying, etc.) that involves a modification of the information.