"Summary of fireproof coatings" report
The "Summary of fireproof coatings" report, accessible from the "Structure" chapter by expanding "Results" and then "Bars", includes a table for each product used, indicating the total quantity of fireproof coating to be applied.
Each table displays the name of the fireproof coating product, the required resistance, and in the various columns, the following information:
- the reference (column "Ref.") of the group of bars where the same solution is applied;
- the reference of the "Bars" included in each group;
- the "Section" of those bars;
- the "Thickness" of the fireproof coating applied to the bars;
- the number of exposed faces (column "Num.");
- the "Surface" to be covered per unit length;
- the total "Length" of the bars;
- and the "Quantity" of product to be applied to each group of bars.
Additionally, at the bottom, the "Total" quantity of each product type is displayed for all bar groups.