Data input and output sequence for designing and analysing sewerage networks
The design and analysis of a sewerage network can be carried out in the program using the following sequence of data input and output:
- Creating a new project (from "File", "New").
- (Optional) Linking to BIMserver.center and importing topographical data from the BIM model.
- Configuring general installation data (in the wizard for creating a new project or via "General data", "Edit general project data"), including the definition of materials and land.
- Defining assumptions and combinations (under "General data", "Edit loadcases"; and under "General data", "Edit combinations").
- (Optional) Importing DXF-DWG/DWF templates or images (from "Edit templates").
- Adding nodes (from "Nodes", "New").
- Adding segments between nodes (from "Segments", "New").
- (Optional) Reviewing and/or adjusting dimensions in the longitudinal sections (from "Longitudinal", "Modify elevations in the longitudinal section").
- Analysing and/or designing the installation (under "Analysis", "Analyse/Design").
- Reviewing the compliance status of the checks performed (via the "Next combination/Select combination/Previous combination" options) and the analysis results (via "Nodes", "Information"; and via "Spans", "Information").
- Printing reports and job drawings (from "File", "Reports/Drawings").
- (Optional) Exporting to BIMserver.center (via "BIMserver.center", "Share").