Selecting and editing reinforcement tables
The "Reinforcement tables" section of the main toolbar contains the options for managing the reinforcement tables used by the program to design the various groups of reinforcement for deep-flange beams:

In the pop-up window that appears when you select any of these options, you can use the "Predefined table" provided by the program by default, a "Library table" (if you have previously created any in the library), or a "Special table" defined specifically for the project.
The available options are as follows:
Horizontal base
This reinforcement table is used to determine the dimensions of the horizontal base reinforcement for the web.
Vertical base
This reinforcement table is used to determine the dimensions of the vertical base reinforcement for the web and the suspension reinforcement.
| Note: |
|---|
| Each entry in the "Horizontal base" and "Vertical base" reinforcement tables is defined by the "Diameter", "Spacing", "Minimum depth" and "Maximum depth". |
Longitudinal
This reinforcement table is used to determine the dimensions of the lower, central and upper longitudinal reinforcement, and the horizontal reinforcement at the supports.
Sloped reinforcement
This reinforcement table is used to determine the dimensions of the sloped reinforcement at the supports.
Reinforcement of indirect loads
This reinforcement layout table is used to determine the dimensions of the reinforcement for indirect loads.
| Note: |
|---|